PERFORMAX
Form No. IS149 (Rev. A 03/11/2008)
ISSPRO, INC.
2515 N.E. Riverside Way
Post Office Box 11177
Portland, Oregon 97211-1899
503-288-4488
800-888-8065
Fax: 503-249-2999
www.isspro.com © 2008 ISSPRO, Inc. All Rights Reserved.
PYROMETER AND THERMOCOUPLE INSTALLATION
INSTRUCTIONS
Models: R43021 R43022 R43031 R43032 R52021 R52022
R52031 R52032 R53021 R53022 R53031 R53032
R59021 R59022 R59031 R59032 R68021 R68022
R68031 R68032 R69021 R69022 R69031 R69032
R82021 R82022 R82031 R82032
I C O N K E Y
CAUTION
Tools may be required
Shown in picture
1
Disconnect batteries. Do not reconnect battery power until system is fully configured to
avoid risk of shock or fire.
2
Install Thermocouple. The Thermocouple mounts
into a ⅛” pipe thread. If the exhaust manifold is already
drilled and tapped, the thermocouple can be installed at the
location. If none is provided, drill (with letter “R” bit) and
tap the hole using ⅛” NPT tap. Apply a small amount of
anti seize lubricant to the exposed threads of the fitting and
tighten using the hex (wrench flats) which are closer to the
tip of the thermocouple. Adjust the depth of the probe (tip
of the probe should be approximately at the center of the
exhaust flow), and tighten the outermost nut no more than
one full turn past finger tight.
3
Install Lead Wire. The lead wire assembly and the thermocouple are supplied with Delphi connectors
for assembly convenience. Simply snap together the connectors at either end of the thermocouple and
lead wire assemblies. Route the terminal end of the lead wire assembly to the Electronic Signal
Processor (ESP), making sure that the lead wire is clear of obstructions that might cut or otherwise
damage it.
Figure 1:
Exhaust, thermocouple and lead wire.